Serial Interface |
|
No. of Ports
|
2
|
Serial Standards
|
RS-232, RS-422, RS-485
|
Baudrate |
50 bps to 921.6 kbps (supports non-standard baudrates) |
Flow Control
|
ADDC® (automatic data direction control) for RS-485
|
Optical Fiber
|
Low-Speed Fiber Module |
Multi-Mode |
Single-Mode |
Fiber Cable Requirements |
50/125 µm, 800 MHz |
G.652 |
62.5/125 µm, 500 MHz |
Typical Distance |
5 km |
40 km |
Wavelength |
Typical (nm) |
850 |
1310 |
TX Range (nm) |
840 to 860 |
1290 to 1330 |
RX Range (nm) |
800 to 900 |
1100 to 1650 |
Optical Power |
TX Range (dBm) |
0 to -5 |
0 to -5 |
RX Range (dBm) |
0 to -20 |
0 to -25 |
Link Budget (dB) |
15 |
20 |
Dispersion Penalty (dB) |
1 |
1 |
|
Pull High/Low Resistor for RS-485 |
1 kilo-ohm, 150 kilo-ohms |
RS-485 Data Direction Control
|
ADDC® (automatic data direction control)
|
Terminator for RS-485
|
N/A, 120 ohms, 120 kilo-ohms
|
Connector |
7-pin terminal block |
Latency |
300 ns |
Serial Signals
|
|
RS-232 |
TxD, RxD, GND |
RS-422
|
Tx+, Tx-, Rx+, Rx-, GND
|
RS-485-4w
|
Tx+, Tx-, Rx+, Rx-, GND
|
RS-485-2w
|
Data+, Data-, GND
|
Power Parameters
|
|
Input Current |
70 to 140 mA @ 12 to 48 VDC |
Input Voltage |
12 to 48 VDC |
No. of Power Inputs |
1
|
Overload Current Protection |
Supported |
Power Connector |
Terminal block |
Power Consumption |
70 to 140 mA @ 12 to 48 VDC
|
Reverse Polarity Protection |
Supported |
Physical Characteristics
|
|
Housing |
Metal |
IP Rating |
IP30 |
Dimensions (with ears)
|
90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)
|
Dimensions (without ears) |
67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in) |
Weight
|
320 g (0.71 lb) |
Installation
|
Wall mounting
|
Environmental Limits
|
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
Operating Temperature
|
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included)
|
-40 to 85°C (-40 to 185°F) |
Standards and Certifications
|
|
EMC
|
EN 55032/24 |
EMI
|
CISPR 32, FCC Part 15B Class A
|
EMS
|
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 1 kV
IEC 61000-4-5 Surge: Power: 1 kV
IEC 61000-4-6 CS: 3 V
IEC 61000-4-8 PFMF
|
Environmental Testing |
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3 |
Safety
|
EN 60950-1, IEC 60950-1
|
Vibration
|
IEC 60068-2-6 |
MTBF
|
|
Time
|
780,480 hrs |
Standards
|
Telcordia (Bellcore), GB |
Warranty
|
|
Warranty Period
|
5 years |
Details
|