Serial Interface |
|
Connector
|
Terminal block
|
No. of Ports
|
2
|
Serial Standards
|
RS-422, RS-485
|
Baudrate |
50 bps to 921.6 kbps (supports non-standard baudrates) |
Isolation
|
TCC-120I: 2 kV
|
Pull High/Low Resistor for RS-485
|
1 kilo-ohm, 150 kilo-ohms
|
RS-485 Data Direction Control |
ADDC® (automatic data direction control) |
Terminator for RS-485
|
N/A, 120 ohms, 120 kilo-ohms
|
Serial Signals
|
|
RS-422
|
Tx+, Tx-, Rx+, Rx-, GND
|
RS-485-4w
|
Tx+, Tx-, Rx+, Rx-, GND
|
RS-485-2w
|
Data+, Data-, GND
|
Power Parameters
|
|
Input Current
|
TCC-120: 65 mA @ 12 VDC
TCC-120I: 180 mA @ 12 VDC
|
Input Voltage
|
12 to 48 VDC
|
No. of Power Inputs
|
1
|
Overload Current Protection
|
Supported
|
Power Connector |
Terminal block (for DC models) |
Power Consumption
|
TCC-120: 65 mA @ 12 VDC
TCC-120I: 180 mA @ 12 VDC
|
Physical Characteristics
|
|
Housing |
Metal |
IP Rating |
IP30 |
Dimensions
|
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
|
Weight
|
148 g (0.33 lb) |
Installation
|
DIN-rail mounting (with optional kit), Wall mounting
|
Environmental Limits
|
|
Ambient Relative Humidity
|
5 to 95% (non-condensing)
|
Operating Temperature
|
Standard Models: -20 to 60°C (-4 to 140°F)
|
Storage Temperature (package included)
|
-40 to 85°C (-40 to 185°F) |
Standards and Certifications
|
|
EMC
|
EN 55032/24 |
EMI
|
CISPR 32, FCC Part 15B Class A
|
EMS
|
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
|
Environmental Testing |
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3 |
Safety
|
EN 60950-1, IEC 60950-1
|
Vibration
|
IEC 60068-2-6 |
MTBF
|
|
Time
|
1,949,025 hrs |
Standards
|
Telcordia (Bellcore), GB |
Warranty
|
|
Warranty Period
|
5 years |
Details
|
See www.moxa.com/tw/warranty |